QUICK LINKS |
|
|
|
 |
| |
|
Home »
Analytical Instruments »
pH Meters |
|
|
Microprocessor Controlled pH Meters
|
|

Model pHA - 1 |

Model pHA - 2 |

Model pHA - 3 |

Model pHA - 4 |

Model pHA - 5 |
|
Art No. |
Description |
| pHA-1 |
Digital pH Meter,
pH Range : 0-14 pH, Resolution : 0.01 pH |
| pHA--2 |
pH/mV/Temp. Analyzer, (Two Point
Calibration)
Having Special Features like Auto Buffer Recognition &
Simultaneous
Display of pH, mV & Temperature Auto / Manual Temp.
Compensation etc. |
| pHA--3 |
pH/mV/Temp. Analyzer (Three Point
Calibration)
Having Special Features like Auto Buffer Recognition &
Simultaneous
Display of pH, mV & Temperature, Auto / Manual Temp.
Compensation,
Last Calibration storage with date and reading of pH, mV
& Offset Value,
Current Results, Printing Facility with calibration data
etc. |
| pHA--4 |
pH/mV/Temp. Analyzer, (Up to 3 / 5
Point Calibration)
Display of pH, mV & Temperature,Parallel & Serial Port
for Printer & PC
attachment, Report Formation as per GLP Compliance 150
Reading Storage
facility with Batch No., Real Date & Time, Operator
Name, Sample Name,
searching of data as per Batch No., Calibration Reminder
Alarm, Results
Hold / Un-Hold Facility etc. |
| pHA--5 |
Microcontroller Based
Handheld pH Analyzer, |
| |
|
| |
|
|
|
|
Model Ph - 01 & Model Ph - 011 with Automatic Temperature
Compensator
|
|
 |
|
Specifications
|
|
Model |
Ph - 01 |
Ph - 011 |
|
PH Range |
00.00 to 14.00 pH |
00.00 to 14.00 pH |
|
mV Range |
+/-1400 mV |
+/-1000 mV |
|
Resolution |
0.1 /0.01pH |
0.1 /0.01pH |
|
Accuracy |
01 / 0.01pH |
01 / 0.01pH |
|
Temperature Set Range |
-5.0 to +135 ° C. |
-5.0 to +135 ° C. |
|
Temperature Resolution |
0.1°C |
0.1°C |
|
Temperature Compensation |
Manual |
Automatic (PT-100) |
|
No. Of Calibration Points |
up to 3 points. |
up to 3 points. |
|
pH Buffer Options |
CD pH Buffers
(4.00,7.00.10.00) |
CD pH Buffers
(4.00,7.00.10.00) |
|
Electrode Input |
Epoxy Body Gel Filled
Alchemie / Mini Electrode. |
Epoxy Body Gel Filled
Alchemie / Mini Electrode. |
|
Display |
Back-lit Graphic Display. |
Back-lit Graphic Display. |
|
Power |
230V 50 Hz / DC 12V
@ 1 Amps |
230V 50 Hz / DC 6V @ 1 Amps |
|
|
|
| Accessories : Optional |
|
|
|
|
|
|
|
‘LOBAlife’ Micro controlled pH SYSTEM |
|
Model
PH61 is a high performance, Micro controller based pH meter
for accurate pH measurements in Chemical, Medical, Research
laboratories and wherever a pH measurement is required. The pC
pH SYSTEM 361 offers automatic temperature compensation as well
as automatic pH standardization for optimum speed and accuracy.
For pH electrodes deviating from the standard Nernst slope,
necessary slope correction is done automatically. The system
reads both pH and temperature, simultaneously, for complete
sample information. Besides pH and temperature measurements, the
unit can be used for measuring Redox potential in its Real mV
mode. It can be also used as general purpose millivoltmeter.
Active operating measuring mode (pH, Rel. mV, CAL, Abs. mV) is
indicated by LED. In standardization (CAL) mode, it
automatically sets the digital read-out to the value of standard
buffer (e.g. 7.00 pH and 4.00 pH or 9.2 pH) after automatically
compensating for the temperature of the solution. Printer
interface is available for hard copy. Standardization remains in
memory. One of the prime features of this system is the
automatic electrode efficiency check to assure good reading.
Moreover, bare minimum controls on front panel and ease of
operation make it handy for routine analysis. The unit is housed
in a compact and light weight two-tone cabinet. |
|
|
| Salient Features |
-
Microcontroller Based
-
Automatic pH Standardisation
-
Two point calibration
-
pH/mV/Temperature measurements
-
Soft touch key operation
-
Automatic/ Manual temperature compensation
-
Calibration Data can be stored in battery back
up memory
-
Printer port (D.M.)
-
Single reading and continuous reading printing
facility in pH & mV measurement mode
-
Seven segment LED display.
|
|
|
|
Specifications
|
|
pH |
|
Range |
0 to 14.00 pH |
|
Resolution |
0.01 pH |
|
Repeatability |
± 0.01 pH ± 1 digit |
|
mV |
|
Range |
0 to ± 1999 |
|
Resolution |
1 mV |
|
Repeatability |
1 mV± 1 digit |
|
Temperature |
|
Range |
0° C to 100°C |
|
Resolution |
0.1°C |
|
Repeatability |
± 0.2° C ± 1 digit |
Temperature compensation
(Auto/Manual) |
0° C to 100° C |
|
Stability |
0.01 pH per hour |
|
Display |
7 digits, 7 segment
LEDs
(3 digits for temp. and 4 digits for pH)
With auto-polarity and decimal point.
Mode annunciation by LED. |
|
Facility |
Printer port only for Dot Matrix Printer |
|
Power requirement |
230V AC. ±10%, 50 Hz |
|
Standard Accessories |
i) pH Electrode (Combined)
ii) Temperature Probe (PT-100 sensor)
iii) Electrode Stand & Clamp
iv) Instruction Manual |
|
Optional |
i) Redox Electrode (Pt. Electrode )
ii) Calomel Electrode
iii) 80 Column Dot Matrix Printer |
|
Dimensions |
250mm (W) x 240mm (D) x 110 mm (H) |
|
Weight |
2.2 kg. Approx. |
|
|
|
|
|
|
pH System PH62
‘LOBAlife’
pH System PH62 is an intelligent high resolution and
precise instrument. It measures pH of a solution, using a pH
electrode. The unit can also measure millivolt (mV) generated by
the sensing electrode. It is named as mV-Absolute when the unit
is asked to work like a conventional voltmeter and as
mV-Relative when the voltage is measured with reference to a 7
pH solution. Facility to measure temperature using a Pt 100
sensor is also provided. The unit offers pH range from 0 to
14.000; mV-absolute up to ± 1999.9 mV; mV-Relative up to ±
1999,9 mV; temperature from 0 to 99.9°C. |
|
|
| Salient Features |
-
Micro Controller based.
-
Measures pH, mV-Absolute, mV-Relative and
temperature.
-
2-point and 3-point calibrations for pH.
-
Automatic and Manual temperature compensation.
-
Single reading facility for pH.
-
80 readings of PH can
be stored in battery back-up memory and retrieved through a
printer.
-
Centronics printer
port offered is compatible with Epson dot-matrix or similiar
for graph and data.
-
RTC (Real Time Clock) mode, when activated,
shows current date and time.
-
2-line, 20-character alphanumeric display.
-
Soft touch numeric and functional keys.
-
A buzzer draws user attention at the end of
wait period / measurement
-
Facility to measure slope of electrode
|
|
|
|
Specifications
|
|
pH |
|
Range |
0 to 14 pH |
|
Resolution |
0.001 pH |
|
Stability |
0.002 pH per hour |
|
Relative Accuracy |
± 0.002 pH ± 1 Digit Acceptable |
|
Electrode Slope |
85% to 115% |
|
Standard Buffers |
1.679, 4.004, 7.000, 9.183, 12.454 Acceptable |
|
Buffer Deviation |
± 0.5 pH |
|
Other working buffers |
0 to 14 pH (value entered through numerical keys) |
|
mV |
|
Range |
(i) mV -Absolute 0 to ± 1999.9 mV,
(ii) mV-Relative 0 to + 1999.9 mV
(with reference to 7 pH buffer) |
|
Resolution |
0.1mV |
|
Accuracy |
± 0.5 mV ± 1 Digit,
or ± 0.05‘)/0 of reading, whichever is greater |
|
Temperature |
|
Range |
0 to 99.9°C |
|
Resolution |
0.1°C |
|
Accuracy |
± 0.5°C ± 1 Digit |
|
General |
|
Inputs |
(i) BNC for pH/mV
single/combined sensing electrode.
(ii) Socket (4mm banana) for external reference electrode.
(iii) Pt for temperature probe. |
|
Display |
2 line, 20 -character alphanumeric LCD |
|
Annunciation |
Individual LED with
keys for calibration, pH, ABS mV, REL mV and print. |
|
Printer Port |
25 - pin, D type;
compatibility with Epson or similiar dot matrix. |
|
Power Supply |
230 V AC ± 10%, 50Hz. |
|
Dimensions |
305 mm (W) 265 mm (D) 125 mm (H) |
|
|
|
|
 |
|
|
|
|
|
|
|